K-PATENTS - PR-23-AC 製藥業濃度計 (選配實驗室用Cuvette進行確效)


符合法規規範   提升製藥生產效能

K-Patents Process Refractometer PR-23 meets the pharmaceutical industry standards and guidelines. These include PAT, GMP, CIP/SIP, 21 CFR Part 11 and validation. The ability to understand and continuously control Refractive Index nD contributes significantly to the development of effective drugs and efficient manufacturing processes.

K-Patents Pharma Refractometer PR-23-AC fulfills the pharmaceutical drug production regulations for process wetted part materials, sealing, and surface roughness. No animal originated media are used in the machining and polishing processes.

Each sensor is provided with a calibration certificate comparing a set of standard liquids to the actual sensor output. Therefore, the calibration and accuracy can be routinely verified with the traceable standard Refractive Index liquids.

Validation often includes the qualification of systems and equipment. It is a requirement for Good Manufacturing Practices (GMPs) and other regulatory requirements. K-Patents provides a validation procedure and equipment that help the user to prove the suitability of the refractometer for its designated function. These include an optional laboratory test cuvette for easy off-line testing of drug samples in the laboratory.


Key Features:

  • Universal calibration of each sensor: All sensors are freely interchangeable.
  • Full measurement range Refractive Index (nD) 1.3200 – 1.5300, which corresponds to 0-100 Brix/Conc.
  • Meets 3A Sanitary Standard and tested for CIP cleanability according to EHEDG.
  • Withstands CIP cleaning.
  • Completely digital system: particles and bubbles do not affect operation or accuracy.
  • Patented CORE-optics: no drift, no re-calibration, no mechanical adjustments.
  • Includes an Ethernet communication solution for data-logging. Together with the user's own procedural and administrative user controls this facilitates electronic data records for FDA 21 CFR Part 11 adherence.
  • Effective heat transfer and isolation using Teflon® and ceramics in the sensor provide safe operation also in higher process temperatures (max. 130 °C/266 °F.
  • Fast process temperature measurement by built-in Pt1000 and automatic temperature compensation.
  • Calibration and accuracy traceability with easy on-site instrument verification using standard Refractive Index liquids.
  • ATEX approved for Zone II, area classification EX II 3 G EEx nA II T4.
  • ATEX approved for Zones 0 and 1, area classification ATEX II 1G Ex ia IIC T4 (only Intrinsically safe PR-23-AC-IA with single sensor transmitter STR).
  • FM approved for Class I, Div. 2, Groups A, B, C and D, T6.
  • CSA certified for Class I, Div. 2, Groups A, B, C and D, T4.
  • cCSAus certified for Electrical Safety, Sensor: Class I, Pollution Deg. 3; Transmitter: Class I, Pollution Deg. 2; Installation Cat. II.

 

 

 