Online - EC-4110-ICON Inductive conductivity Transmitter


Built-in concentration curve and user-defined concentration table

 

Applications:

- Aggressive Chemical Concentration

- Chemical Recycling System

- Reagent Dilution for Recycle Water

- Semiconductor/Electronics Process

- Salinity Adjustment/Desalination

- Food & Beverage CIP

- Scrubber/Cooling Water

- Wastewater Treatment 

 

Features:

- 96 x 96 mm Inductive Conductivity/Salinity/TDS Transmitter

- Max. conductivity range up to 2,000mS/cm compatible with an anti-fouling electrodeless conductivity sensor

- Waterproof and dustproof design

- User-friendly operation with text and graphic illustrations, clear signs and easy to understand

- Equipped with CONCENTRATION function for chemical concentration control

- Built-in chemical concentration curves and a self-defined concentration curve function

- Simultaneous display of Concentration, compensated conductivity, and absolute conductivity value

- Smart dual-way communication allows remote control of settings and concentration curves selection

- Measuring value can be selected for figure or chart display

- Trace mode can display historical measured value curve from 3-minute to 4-week program

- Equipped with logbook function and error diagnosis record

- Large LCM display with auto-sense backlight and contrast setting function

- Equipped with one analog output and RS-485 interface

- Automatic temperature compensation with NTC30K, PT-1000

- Fine tuning of product adjustment function enable process calibration

- Temperature coefficient compensation by programmable linear and non-liner

- Hi/Lo, Hi/Hi, Lo/Lo selectable two limited contact output with programmable set-point and hysteresis

- Gradually continuous sample measurements average function to enhance stability

- With password and multi-key design—security protection enhancement

- LED indicated alarms or washing status signal

- IP 65 (NEMX 4X)

 

EC-4110-ICON equipped with concentration curve as follows:

NaCl_28%: 0~28%  (Range including different temperature condition)

HCl_18%: 0~18%         HCl_39%: 22~39%

HNO3_30%: 0~30%     HNO3_30%: 35~96%

NaOH_24%: 0~24%,    NaOH_50%: 15~50%

H2SO4_37%: 0~37%    H2SO4_88%: 28~88%, H2SO4_99%: 89~99%

H3PO4_35%: 0~35%

User-Defined Concentration Table(9 temp. x 9 Con./Cond. matrix)

 

The EC-4110-ICON transmitter provides precise inductive conductivity measurements even in the harshest chemical conditions with chemical concentration curves, or a self-defined conversion table.

The EC-4110-I is an inductive conductivity transmitter without concentration mode. Built-in product adjustment function allows fine-tuning for concentration values to minimize process contamination caused deviations. Users can even utilize MODBUS digital communication to remotely change concentration curves.